Explosion-Proof RFID Tag

+ ExRFID SA1 TAG

The ATEX Directive/IECEx Scheme and related standards like EN (IEC) 60079 and ISO 80079 define the mandatory lifetime tracking, for the total lifetime of one installation being installed in a possible hazardous area is EX proof. Ex proof means each installation has to be identified.

ExRFID SA1 tag makes it happen in a cost effective way for longterm operation.

  • Passive RFID tag
  • Simple apparatus according to IEC 60079-14
  • Applicable hazardous area classification
    Zone 1 IIC T6 / Zone 21 IIIC 85°C an ambient temperature Tamb 40°C
    Zone 1 IIC T5 / Zone 21 IIIC 100°C at an ambient temperature Tamb 60°C

DENTIFICATION OF ANY INSTALLATION IN POSSIBLE HAZARDOUS AREAS

The ExRFID SA1 has to be installed on each device operated in possible hazardous areas, you need to read it out and then in a database (sheets of maintainance, repair and inspections) it has to managed. Possible solution: tablet, smart phone, RFID reader, and EPDS software

  • ID for mandatory lifetime tracking according to IEC 60079-14
  • Real time identification
  • All assets can be tracked easily
  • Follow up inspection, operation, maintenance, repair
  • Connected via Ex field device, and managed by the EBDS software

TECHNICAL FEATURES

  • 13.56 MHz operating frequency
  • ISO/IEC 15693-2,-3; ISO/IEC 18000-3 Compliant
  • 256-Bit User Memory in 8 x 32-Bit Blocks
  • user and Factory Lock Per Block
  • Application Family Identifier (AFI)
  • Fast Simultaneous Identification (Anti-Collision)
  • operating temperature: -25°C to 90°C
  • storage temperature: -40°C to 120°C (130°C for total 50hrs, 220°C for total 30s)
  • data retention time (at 25°C): >10yrs
  • dimensions: Ø 22 ± 0.2 mm x 3 ± 0.2 mm
  • weight: 2.1 ± 0.2 gramm
  • protection class: IP68
  • vibration: ISO/IEC 68.2.6 (10 g, 10 to 2000 Hz, 3 axis, 2.5 h)
  • mechanical shock: ISO/IEC 68.2.27 (100 g, 6 ms, 6 axis, 20 times per axis)
  • mechanical stability: Axial compression strength: 1000N (10 s, static) Radial compression strength: 500N (10 s, static) Isostatic water pressure: 45 bar (10 h)
  • EU Declaration of Conformity