DAILY Ex - 16 NOVEMBER 2026
TODAY'S FOCUS: The most dangerous conditions may arise outside normal production. A fatal methane explosion in Colombia, a newly documented chemical release during decommissioning in the United States, and reported damage to Russian petrochemical infrastructure lead today's edition. For Heads of Operations: Explosion protection must address the full lifecycle of industrial equipment, including shutdown, cleaning, decommissioning, maintenance and abnormal operating conditions.

⚡ DAILY Ex | 16 NOVEMBER 2026
Explosion Protection | Operational Ex | Global Watch
TODAY'S FOCUS: The most dangerous conditions may arise outside normal production.
A fatal methane explosion in Colombia, a newly documented chemical release during decommissioning in the United States, and reported damage to Russian petrochemical infrastructure lead today's edition.
For Heads of Operations: Explosion protection must address the full lifecycle of industrial equipment, including shutdown, cleaning, decommissioning, maintenance and abnormal operating conditions.
🔴 1. COLOMBIA | Four killed in underground coal-mine explosion
CURRENT INCIDENT · 13–15 NOVEMBER
Four miners died following a methane explosion at the La Victoria coal mine in Chita, Boyacá. Rescuers recovered the final two bodies on Sunday, 15 November.
Colombia's National Mining Agency reported that rescue operations had ended and mining activities were suspended while the investigation continued.
Why it matters operationally: Underground mining combines methane accumulation, ventilation dependencies, ignition sources and potentially combustible coal dust. The initiating circumstances have not yet been established.
Management action: Review methane monitoring, ventilation failure responses, electrical and non-electrical ignition sources, and emergency withdrawal criteria.
https://apnews.com/article/77de9fe1831a8c03696e617149bb92d9
🔴 2. USA | Hydrogen sulfide release during scrubber decommissioning
NEW OFFICIAL INCIDENT REPORT · 13 NOVEMBER
The US Environmental Protection Agency documented a chemical release at Lubrizol's Deer Park facility in Texas on 10 November.
During scrubber decommissioning, residual material was processed through a treatment system. The system overpressurised, releasing hydrogen sulfide. Fence-line monitors detected elevated concentrations.
According to the company's account recorded by EPA, phosphorus pentasulfide reacted with water during treatment operations.
Why it matters operationally: A system being taken out of service may contain reactive residues. Cleaning and disposal operations can introduce chemical reactions not encountered during normal production.
This is a reported toxic-gas release, not a confirmed explosion. Hydrogen sulfide is also flammable, making release assessment important for both toxic and ignition hazards.
Management action: Require documented chemical-compatibility reviews, residual-inventory assessments, pressure-control verification and emergency arrangements before decommissioning.
https://storymaps.arcgis.com/stories/9023c462049347c897b534c1bb006692
🔴 3. RUSSIA | Reported drone strike at petrochemical complex
CURRENT REPORTS · 15 NOVEMBER
Ukraine reported strikes on industrial targets in Russia, including petrochemical facilities in Nizhnekamsk, Tatarstan.
Photographs and videos circulated showing a reported fire near industrial infrastructure. The precise damage, operational consequences and affected equipment have not been independently established.
Why it matters operationally: External damage can compromise containment, fire protection and emergency shutdown systems simultaneously.
Management action: Verify that site emergency procedures address loss of utilities, damaged equipment and the conditions required before restarting affected units.
⚖️ 4. GLOBAL | IECEx service facilities and repair competence
CERTIFICATION PRACTICE · EVERGREEN
IECEx maintains an approved Certification Body network for the Certified Service Facility Scheme, including repair, overhaul and reclamation under IEC 60079-19.
Why it matters operationally: A contractor's general Ex experience does not establish competence for every protection concept or repair activity.
Management action: Verify the facility's current certificate, technical scope, repair documentation and release authorisation before placing work.
https://www.iecex.com/who-we-are/excbs/service-facilities/
🔬 5. UK | New technical work on hydrogen ventilation and Ex barriers
UPCOMING TECHNICAL PRESENTATIONS · 17–19 NOVEMBER
The published Hazards 36 programme includes Gexcon research on ventilation of large hydrogen compressor enclosures, HSE discussions on why major-accident barriers fail, and an Energy Institute presentation on technical change management.
The hydrogen study uses CFD to investigate how ventilation arrangements influence gas accumulation under realistic leak scenarios. These are scheduled presentations, not yet independently evaluated conference findings.
Why it matters operationally: Ventilation effectiveness depends on actual enclosure geometry, leakage scenarios and airflow-not simply the presence of a fan.
Management action: Verify ventilation assumptions and protective-function performance against credible operating and failure conditions.
https://www.icheme.org/training-events/hazards-process-safety-conference/programme/
⚙️ 6. TECHNOLOGY | Digital barrier management meets Operational Ex
INDUSTRY TECHNOLOGY WATCH · NOVEMBER 2026
Hazards 36 will feature presentations from Eigen and Aker BP on monitoring operational barrier elements, alongside ADNOC Offshore's work on AI-assisted process engineering and PRIO's work on gas-detection coverage degradation.
Why it matters operationally: A barrier register can show that a protective system exists without demonstrating that it is available, tested and supported by competent personnel.
Management action: Connect inspection findings, maintenance defects, bypasses and overdue corrective actions to a live view of safety-critical barrier health.
📅 7. MANCHESTER | Hazards 36 begins tomorrow
UPCOMING EVENT · 17–19 NOVEMBER
IChemE's conference will address process-safety leadership, major-accident prevention, hydrogen, battery storage, digitalisation and practical lessons from industrial operations.
A separate organisational-learning event is scheduled for today, 16 November, examining the gap between written procedures and actual work.
Why it matters operationally: Effective protection depends on both engineering safeguards and the decisions made by people operating and maintaining them.
https://www.icheme.org/training-events/hazards-process-safety-conference/
▶️ OPERATIONAL Ex USE CASE
THE POWDER MIXER - WHEN CLEANING CREATES A NEW EXPLOSION HAZARD
ILLUSTRATIVE SCENARIO
A chemical manufacturer operates a powder mixer processing combustible organic materials.
During normal production, the process is dry and the explosion-protection assessment considers the relevant dust atmosphere and mechanical ignition sources.
Maintenance proposes wet cleaning before introducing a different product.
However, residual chemicals inside the mixer may react with the cleaning liquid, generating heat or flammable gas.
The cleaning operation may also affect mechanical seals, electrical equipment and instrumentation.
What must Operations establish before authorising cleaning?
The assessment must cover chemical compatibility, residual inventories, reaction products, ventilation, ignition sources, equipment suitability and safe disposal.
Owner: Operations Manager, supported by Process Engineering, Maintenance and the Ex Responsible Person.
Required evidence: Cleaning procedure, chemical-compatibility assessment, residual-inventory verification, atmospheric testing where appropriate and return-to-service authorisation.
STOP criterion: No cleaning where the reaction behaviour or potential for hazardous-atmosphere formation remains unresolved.
Performance measure: 100% of non-routine cleaning methods assessed and authorised before execution.
▶️ TODAY'S CRITICAL Ex QUESTION
A powder-processing vessel is cleaned with water, but residual material may react to generate flammable gas. What is the primary engineering requirement?
A. Confirm the motor remains Ex-certified.
B. Increase ventilation without further assessment.
C. Assess chemical compatibility, gas generation and ignition hazards before cleaning. ✅
D. Treat the cleaning activity as non-hazardous because production has stopped.
The hazardous atmosphere during cleaning may be fundamentally different from the atmosphere considered during normal production.
⚡ DAILY Ex | CLOSING THOUGHT
Today's incidents demonstrate why the boundaries of explosion protection must extend beyond routine production.
A coal mine can accumulate methane.
A scrubber can generate hazardous gas during decommissioning.
A powder mixer can develop a new ignition hazard during cleaning.
And a petrochemical installation can lose several protective systems through one external event.
For Heads of Operations, the question is not only whether the process is safe while producing. It is whether the complete installation remains safe throughout every stage of its operating life.
Production, maintenance, cleaning and decommissioning are all part of Operational Ex.