DAILY ExPublished: November 2026Author: Veress Árpád · Explosion-protection expert

DAILY Ex - 18 NOVEMBER 2026

TODAY'S FOCUS: When the process is interrupted, the explosion risk does not disappear. A gas-well release during maintenance in India, an explosion and fire at a US hazardous-waste facility, and a cyberattack affecting an international energy company bring a common operational question into focus: Can we demonstrate that protective barriers remain effective during abnormal conditions?

Three-panel industrial illustration showing a cyberattack on an energy company's IT and operational systems and its potential consequences for explosion protection. The image highlights IT/OT vulnerabilities, loss of process control, ignition risks, safety-system failures and essential cybersecurity and operational safety measures.

⚡ DAILY Ex | 18 NOVEMBER 2026

Explosion Protection | Operational Ex | Global Watch

TODAY'S FOCUS: When the process is interrupted, the explosion risk does not disappear.

A gas-well release during maintenance in India, an explosion and fire at a US hazardous-waste facility, and a cyberattack affecting an international energy company bring a common operational question into focus:

Can we demonstrate that protective barriers remain effective during abnormal conditions?


🔴 1. INDIA | ONGC controls gas leak during well workover

CURRENT INCIDENT · 17 NOVEMBER

India's ONGC reported a gas release from a well in Andhra Pradesh's Konaseema district during workover operations. The leak began at approximately 05:00 local time and was controlled by around 15:00.

No injuries or fatalities were reported. Authorities established a precautionary 500-metre cordon, temporarily restricted electrical power and moved nearby residents to safety.

Why it matters operationally: Maintenance can change containment boundaries, pressure conditions and the location of hazardous atmospheres. Existing hazardous-area classifications may not adequately represent every temporary release scenario.

Management action: Verify well-control barriers, temporary hazardous-area arrangements, ignition-source restrictions, gas monitoring and return-to-service criteria.

https://www.reuters.com/business/energy/indias-ongc-initiates-well-control-ops-after-gas-leak-andhra-pradesh-well-2026-11-17/


🔴 2. USA | Explosion and fire at hazardous-waste incineration facility

BREAKING INCIDENT REPORT · 17 NOVEMBER, EVENING

Emergency services responded to reports of an explosion and fire at Clean Harbors' Deer Park incineration facility in Texas.

A community emergency notification identified an explosion, fire and process or unit upset. At approximately 22:00 local time, authorities reported that the fire was continuing, but no protective action was required for nearby La Porte residents. Initial air monitoring showed no hazardous readings.

The cause, equipment involved and any casualties were not established in the initial report.

Why it matters operationally: Hazardous-waste processing may involve variable chemical composition, incompatible materials, combustible liquids, reactive residues and abnormal thermal conditions. The event is not yet established as an ATEX-type atmospheric explosion.

Management action: Review incoming-waste characterisation, compatibility checks, abnormal-temperature protection and emergency isolation.

https://www.houstonchronicle.com/news/houston-texas/article/blast-fire-reported-clean-harbors-facility-la-22536703.php


🔴 3. NORWAY | Equinor reports cyberattack

CURRENT DEVELOPMENT · 17 NOVEMBER

Equinor confirmed a cyberattack affecting some IT systems. The company reported no impact on oil and gas production and no indication that data had been stolen.

Norway's National Security Authority was aware of the incident and assisting.

Why it matters operationally: This is not an explosion incident, and no operational safety-system compromise has been reported. Nevertheless, cyber resilience matters wherever maintenance systems, permits, engineering records or monitoring data support Ex-safe operations.

Management action: Verify the availability of critical documentation, inspection records and safe operating procedures during IT outages. Confirm that operational technology and safety-system dependencies are understood.

https://www.reuters.com/technology/equinor-detects-ongoing-cyberattack-output-unaffected-2026-11-17/


⚖️ 4. ATEX / IECEx | Temporary hazardous conditions require explicit control

REGULATORY PRACTICE · EVERGREEN

Directive 1999/92/EC requires employers to assess explosion risks and implement appropriate organisational and technical measures.

IEC 60079-10-1 provides the framework for classifying areas where flammable gas atmospheres may occur; IEC 60079-14 and IEC 60079-17 address electrical installation and inspection.

Operational significance: A temporary maintenance activity may introduce a release source or operating condition not covered by the routine installation assessment.

Management action: Ensure permits, isolation plans and temporary equipment selection reflect the actual task—not merely the permanent zone drawing.

https://eur-lex.europa.eu/eli/dir/1999/92/oj/eng · https://www.iecex.com/


🔬 5. RESEARCH | Small explosions, major consequences

CONFERENCE RESEARCH WATCH · 18 NOVEMBER

Hazards 36 includes a technical presentation on smaller-scale industrial explosions involving volatile liquids and combustible dusts.

The announced research addresses knowledge gaps and opportunities to improve understanding, training and risk management. These are program topics, not yet independently verified final findings.

Why it matters operationally: Small batch vessels, laboratory apparatus and compact machinery can still experience dangerous pressure development or flame propagation.

Management action: Avoid excluding equipment from explosion-risk assessments solely because its inventory is relatively small.


⚙️ 6. TECHNOLOGY | From operational data to barrier decisions

CURRENT INDUSTRY EVENT · 18 NOVEMBER

Today's Hazards 36 programme features Sphera's presentation on operational digital twins, connecting hazard studies, barrier status, maintenance, permits and Management of Change.

The conference also addresses incident investigation and lessons from industrial losses.

Why it matters operationally: Digitalisation delivers limited safety benefit unless it helps identify degraded safeguards and supports timely decisions.

Management action: Connect Ex inspection findings, repair status, temporary modifications and safety-critical defects to clear operational ownership.

https://www.icheme.org/training-events/hazards-process-safety-conference/programme/


▶️ OPERATIONAL Ex USE CASE

THE GAS COMPRESSOR - WHEN A MAINTENANCE VENT BECOMES AN IGNITION HAZARD

ILLUSTRATIVE SCENARIO · GAS / NON-ELECTRICAL / TEMPORARY OPERATIONS

A gas compressor is shut down for seal replacement.

The permanent installation is designed for its assessed hazardous-area conditions, but the maintenance team proposes using a temporary flexible hose to vent residual gas.

The proposed discharge location is close to portable electrical equipment and a vehicle route.

The compressor is stopped. The hazardous atmosphere may not be.

Critical Ex question: Has the temporary vent arrangement been assessed as a new release source, including dispersion, discharge location, ignition sources, bonding, ventilation and operating conditions?

Owner: Maintenance Manager, supported by Operations, Process Engineering and the Ex Responsible Person.

Required evidence: Approved isolation and depressurisation procedure, vent arrangement, task-specific hazardous-area assessment, equipment suitability and gas-testing plan.

STOP criterion: No venting until the discharge location, release consequences and ignition-source controls have been verified and authorised.

KPI: 100% of non-routine gas venting operations covered by approved task-specific controls.


▶️ TODAY'S CRITICAL Ex QUESTION

A temporary gas-vent hose is installed during compressor maintenance. The permanent hazardous-area classification drawing shows the nearby location as non-hazardous. What is the correct engineering approach?

A. Accept the permanent classification without further assessment.

B. Use any electrical equipment because the compressor is stopped.

C. Assess the temporary release source and resulting ignition hazards. ✅

D. Require Ex d equipment everywhere, regardless of the assessment.

Temporary releases can create hazardous atmospheres beyond the conditions represented by permanent area-classification drawings. The appropriate controls must be determined from the actual release scenario.


⚡ DAILY Ex | CLOSING THOUGHT

Three developments, three different operational challenges:

A gas well loses containment during maintenance.

A hazardous-waste facility experiences an explosion and fire.

An energy company faces a cyberattack without reported production disruption.

The common lesson is not that every event is an ATEX incident.

It is that Operational Ex depends on knowing which barriers are required, whether they remain available and who can authorise continued operation.

A safe process is not defined by the absence of an incident. It is demonstrated by the integrity of its protective measures.