DAILY Ex - 23 NOVEMBER 2026
TODAY'S FOCUS: When protection depends on what happens outside the certified equipment. This edition examines an often-overlooked Operational Ex problem: the interface between machinery, utilities, protective systems and the people responsible for operating them. The key question for Heads of Operations is whether the complete installation remains safe when one supporting condition changes or fails.

⚡ DAILY Ex | 23 NOVEMBER 2026
Global Explosion Protection Watch | Head of Operations Edition
TODAY'S FOCUS: When protection depends on what happens outside the certified equipment.
This edition examines an often-overlooked Operational Ex problem: the interface between machinery, utilities, protective systems and the people responsible for operating them.
The key question for Heads of Operations is whether the complete installation remains safe when one supporting condition changes or fails.
1. INDONESIA | Factory fire death toll feared to rise
BREAKING UPDATE · 23 NOVEMBER
A major new development in the PT Fonusa Agung Mulia confectionery factory fire in Banten: police have recovered human remains in 24 body bags. Authorities have not yet established the final number of fatalities, and identification work continues. Earlier reporting identified 34 missing workers and 29 survivors among 63 people believed to have been in the affected area.
The fire started on 21 November. Its cause remains unconfirmed. There is no verified finding of a combustible-dust explosion.
Why it matters operationally: Food manufacturing combines process machinery, combustible materials, electrical utilities and sometimes combustible dust. Effective evacuation and personnel accountability are as important as preventing ignition.
Management action: Verify emergency exits, personnel accounting, utility isolation and whether combustible-dust hazards have been separately assessed.
2. USA | Adhesives plant explosion leaves two injured
RECENT INCIDENT · 20 NOVEMBER
Two people were injured in an explosion at Volunteer Adhesives in Lafayette, Tennessee, with one reported in critical condition. The available reporting does not establish the initiating cause or the materials involved.
Why it matters operationally: Adhesive production can involve solvent vapours, heated materials, powders and reactive formulations. The actual hazard depends on the process and ingredients; the incident should not yet be classified as a vapour explosion.
Management action: Recheck batch-change controls, chemical compatibility, ventilation, static-electricity management and process-temperature limits.
https://fox17.com/news/local/reported-lafayette-factory-explosion-leaves-two-injured-one-critical
3. EU | Type 'n' harmonised standard transition
REGULATORY DEVELOPMENT · 10 NOVEMBER
Commission Implementing Decision (EU) 2026/2480 cites EN IEC 60079-15:2019 together with A11:2026 under Directive 2014/34/EU. The previous EN 60079-15:2010 reference has a cessation date of 10 May 2028.
Why it matters operationally: Procurement and conformity-assessment documentation must follow the applicable harmonised references. This does not automatically require replacement of previously installed compliant equipment.
Management action: Update standards registers and check certificates and declarations for new Zone 2 equipment purchases.
https://eur-lex.europa.eu/eli/dec_impl/2026/2480/oj/eng
4. IECEx | Certification quality and competence
RECENT INDUSTRY REPORT · 6 NOVEMBER
A review of IECEx's 30th-anniversary meetings in Beijing highlighted peer-assessor training, Quality Assessment Report oversight and technical nonconformity case studies.
Why it matters operationally: Certification reliability depends on consistent technical assessment and ongoing quality-system surveillance, not only initial testing.
Management action: Check the validity and actual scope of Ex certificates, service-facility approvals and personnel competence before accepting suppliers.
https://www.hazardexonthenet.net/article/224940/Celebrating-30-years-of-the-IECEx.aspx
5. IEC | Equipment assemblies under development
STANDARDS WATCH · PROJECT STATUS
IEC 60079-46 Edition 1 addresses complete equipment assemblies, including ignition hazards introduced when individually certified items are integrated. The accessible project record shows publication preparation, but does not conclusively verify final publication.
Why it matters operationally: A packaged pump, analyser or compressor skid may introduce new thermal, mechanical and electrical hazards despite its certified components.
Management action: Require a documented assembly-level assessment at procurement and commissioning.
https://dps.gov.al/en/project/show/iec%3Aproj%3A107159
6. TECHNOLOGY | Ex repair needs evidence, not just a functional test
ENGINEERING PRACTICE · IEC 60079-19
IECEx service-facility certification addresses technical capability, quality systems and competent personnel for defined repair activities.
Why it matters operationally: A repaired motor may run correctly while still having unacceptable flamepath dimensions, incorrect replacement parts or inadequate documentation.
Management action: Require repair measurements, acceptance criteria, competent release authorisation and installation verification before restart.
https://www.sgs.com/en-fr/services/iecex-service-facility-certification
▶️ OPERATIONAL Ex USE CASE
THE NITROGEN-PURGED ANALYSER - WHEN THE UTILITY PRESSURE FALLS
ILLUSTRATIVE SCENARIO · PRESSURISATION PROTECTION
A process analyser is installed in a Zone 1 gas hazardous area. Its enclosure uses a certified Ex p pressurisation system to prevent a flammable atmosphere from contacting internal ignition-capable components.
During production, nitrogen supply pressure drops below the protective system's permitted operating limit. The analyser continues reporting valid process measurements.
Operations proposes keeping it energised because no gas alarm has activated.
The critical question: Is the enclosure still maintaining the protection conditions required by its certification and IEC 60079-2?
A valid analyser reading does not prove that pressurisation protection remains effective. Depending on the specific protection type and certified arrangement, loss of pressure may require an alarm, automatic de-energisation or another prescribed protective response.
Owner: Instrumentation Manager, supported by Operations and the Ex Responsible Person.
Required evidence: Equipment certificate, protection type, manufacturer instructions, minimum pressure and flow settings, protective-system test results, and documented fault-response logic.
STOP criterion: Do not continue operating ignition-capable internal equipment where the required pressurisation protection is lost and the certified fault response cannot be demonstrated.
KPI: 100% of Ex p protective-function faults investigated and dispositioned before reset or restart.
▶️ TODAY'S CRITICAL Ex QUESTION
An Ex p analyser enclosure loses its required protective pressure, but the analyser still operates normally. What determines whether it may remain energised?
A. Whether the analyser continues to display valid measurements.
B. Whether the surrounding gas detector has activated.
C. The certified Ex p protection type, fault-response requirements and verified protective functions. ✅
D. Whether the nitrogen supply is expected to recover shortly.
The required response depends on the applicable pressurisation protection concept, equipment certification and fault conditions. Functional process measurements do not override explosion-protection requirements.
⚡ DAILY Ex | CLOSING THOUGHT
A certified analyser may become unsafe when its protective nitrogen supply fails.
A repaired motor may function without its explosion-protection integrity being demonstrated.
An assembly may contain certified components yet introduce new ignition hazards through integration.
For Heads of Operations, the essential question is not simply whether the equipment works. It is whether the conditions that make its operation safe still exist.