DAILY ExPublished: November 2026Author: Veress Árpád · Explosion-protection expert

DAILY Ex - 24 NOVEMBER 2026

TODAY'S FOCUS: When protective measures exist, but their effectiveness has not been demonstrated. A recovery boiler explosion in Brazil, new hydrogen explosion research and tomorrow's hazardous-area conference in the UK bring together three important operational priorities: asset integrity, protection-system effectiveness and confidence in equipment conformity.

Technical illustration of a flexible solvent-transfer hose connecting a flammable-liquid container to a tanker. An electrical continuity measurement of 0.3 ohms between the metallic fittings is shown alongside a warning that the hose's internal lining may still present an electrostatic ignition hazard.

⚡ DAILY Ex | 24 NOVEMBER 2026

Global Explosion Protection Watch | Head of Operations Edition

TODAY'S FOCUS: When protective measures exist, but their effectiveness has not been demonstrated.

A recovery boiler explosion in Brazil, new hydrogen explosion research and tomorrow's hazardous-area conference in the UK bring together three important operational priorities: asset integrity, protection-system effectiveness and confidence in equipment conformity.


🔴 1. BRAZIL | Recovery boiler explosion shuts down paper mill

NEW INCIDENT REPORT · 23 NOVEMBER

An explosion involving recovery boiler CR-04 at Klabin's paper mill in Otacílio Costa, Santa Catarina, injured eleven workers on 18 November.

The incident resulted in a release of process liquor and suspension of mill operations. The affected facility has an annual production capacity of approximately 330,000 tonnes of kraftliner paper.

The initiating failure mechanism remains under investigation. A combustible-atmosphere explosion has not been established.

Why it matters operationally: Recovery boilers combine combustion, chemical recovery, high temperatures and pressure-related hazards. Failure of a single critical asset can interrupt an entire production facility.

Management action: Review boiler integrity, protective interlocks, abnormal-operation procedures and restart authorisation criteria.

https://www.hazardexonthenet.net/article/225234/Explosion-at-recovery-boiler-in-Brazilian-paper-mill-injures-11.aspx


🔴 2. INDONESIA | Authorities investigate factory safety protocols

MATERIAL FOLLOW-UP · 23 NOVEMBER

Reuters reports that authorities have confirmed 24 fatalities following the confectionery factory fire in Banten.

An electrical fault associated with an air-conditioning system has emerged as a preliminary possibility. Authorities are also examining factory safety arrangements. Neither the ignition mechanism nor the involvement of combustible dust has been established conclusively.

Why it matters operationally: Auxiliary equipment, including cooling and ventilation systems, must be considered within the overall facility risk assessment.

Management action: Include utility equipment in ignition-source assessments, preventive maintenance and emergency isolation plans.

https://www.reuters.com/world/asia-pacific/indonesia-says-24-killed-factory-blaze-rescuers-search-dozens-missing-2026-11-23/


🔬 3. RESEARCH | Hydrogen explosion suppression depends on more than water quantity

NEW SCIENTIFIC PUBLICATION · 16 NOVEMBER

Research published in the International Journal of Hydrogen Energy examines the effectiveness of ultrafine water mist in suppressing hydrogen deflagrations within confined spaces.

Numerical modelling indicates that droplet characteristics, spatial distribution and the relationship between evaporation and flame propagation influence suppression effectiveness.

Why it matters operationally: Installing a water-mist system does not automatically establish effective hydrogen explosion suppression.

Management action: Require application-specific validation before crediting suppression systems as explosion-protection barriers. Research findings alone do not establish conformity or suitability for an industrial installation.

https://doi.org/10.1016/j.ijhydene.2026.158128


🤖 4. TECHNOLOGY | Physical AI enters hazardous areas

NEW INDUSTRY PUBLICATION · 23 NOVEMBER

ANYbotics has presented further details of its ANYmal X autonomous inspection robot for Zone 1 applications. Yesterday's publication identifies an EU-type examination certificate issued by Bureau Veritas in October 2026:

EPS 26 ATEX 1 263 X

The manufacturer highlights durability testing, actuator reliability, environmental resistance and maintenance arrangements, including the replacement of selected components on site.

The critical Ex considerations:

* Mechanical impacts, falling and collisions.

* Ageing of seals and electrostatic protection.

* Battery and actuator replacement.

* Payload configuration and certification boundaries.

* Periodic inspection and repair competence.

Why it matters operationally: The economic viability of autonomous Ex robotics depends not only on initial certification but also on maintaining explosion-protection integrity throughout its operational lifetime.

Management action: Obtain the actual certificate, special conditions of use, permitted configurations and manufacturer maintenance instructions before deployment. The certificate number is manufacturer-reported and has not been independently examined for this edition.

https://www.hazardexonthenet.net/article/225229/Physical-AI-Enters-the-Hazardous-Area.aspx


📅 5. UK | Hazardex Swansea takes place tomorrow

UPCOMING INDUSTRY EVENT · 25 NOVEMBER

Hazardex in the Regions will bring together hazardous-area professionals in Swansea tomorrow.

The announced programme includes UK HSE developments, electrostatic discharge prevention, counterfeit Ex equipment and certificates, and competence requirements in Ex manufacturing.

Participating manufacturers and suppliers include R. STAHL, Newson Gale, Roxtec, Blackline Safety, ABTECH and i.safe MOBILE.

Why it matters operationally: Counterfeit equipment, uncontrolled electrostatic hazards and insufficient competence can undermine even a well-designed explosion-protection strategy.

Management action: Review supplier approval procedures, electrostatic risk assessments and technical acceptance criteria for incoming Ex equipment.

https://www.hazardex.live/event-details/hazardex-in-the-regions-swansea-1


⚖️ 6. IECEx / ATEX | A certificate PDF is not sufficient evidence

COMPLIANCE AND PROCUREMENT PRACTICE · EVERGREEN

IECEx explicitly identifies its online certification system as the controlled master source for IECEx certificates. Downloaded and printed copies are uncontrolled documents.

Certificate status, issue number, equipment configuration and special conditions must be considered during technical acceptance. Suspension or cancellation also requires consideration of the equipment's manufacturing date.

Why it matters operationally: An authentic but outdated certificate may not accurately represent the supplied equipment or its current certification status.

Management action: Establish certificate verification as a mandatory procurement and incoming-inspection activity, distinguishing IECEx verification from the applicable ATEX conformity-assessment route.

https://www.iecex.com/certified-equipment-scheme/faqs-certified-equipment-scheme/


▶️ OPERATIONAL Ex USE CASE

THE SOLVENT TRANSFER HOSE - WHEN ELECTRICAL CONTINUITY DOES NOT PROVE ELECTROSTATIC SAFETY

ILLUSTRATIVE SCENARIO · NON-ELECTRICAL EXPLOSION PROTECTION

A chemical plant replaces a flexible solvent-transfer hose with a mechanically compatible alternative.

The new hose has metallic end fittings. Maintenance measures electrical continuity between the fittings and accepts the assembly for operation.

However, the internal lining has different electrostatic properties from the original hose.

The continuity measurement confirms an electrical connection between the fittings. It does not necessarily demonstrate that electrostatic charge generated at the internal surface can dissipate safely.

The critical question: Is the complete hose assembly suitable for the actual liquid, flow conditions and electrostatic charging mechanisms?

Relevant technical references include IEC TS 60079-32-1, IEC 60079-32-2 and EN 12115, where applicable.

Owner: Operations Manager, Mechanical Engineering and Ex Responsible Person.

Required evidence: Hose construction and electrical properties, manufacturer documentation, liquid conductivity, bonding arrangements, operating limits and application-specific electrostatic assessment.

STOP criterion: Do not introduce the replacement hose into flammable-liquid service until its electrostatic suitability has been demonstrated.

KPI: 100% of replacement hoses used for flammable-material transfer subject to documented technical acceptance.


▶️ TODAY'S CRITICAL Ex QUESTION

A solvent-transfer hose passes an electrical continuity test between its metallic end fittings. Does this automatically demonstrate electrostatic safety?

A. Yes, electrical continuity eliminates electrostatic hazards.

B. Yes, provided both fittings are metallic.

C. No, internal surface properties and charging mechanisms must also be assessed. ✅

D. Only the pump's Ex certificate matters.

Electrical continuity between fittings does not necessarily establish the electrostatic behaviour of the hose lining or the complete transfer system under actual operating conditions.


⚡ DAILY Ex | CLOSING THOUGHT

A hydrogen suppression system may deliver water without providing effective explosion suppression.

An autonomous Ex robot may retain its certificate while its physical protection deteriorates.

A solvent-transfer hose may pass a continuity test while retaining an electrostatic ignition hazard.

The existence of a protective measure is not evidence of its effectiveness.

For Heads of Operations, the responsibility is to establish what each protective measure actually achieves, under which conditions it remains effective, and how its integrity is verified throughout the operational lifecycle.