DAILY Ex - 26 NOVEMBER 2026
TODAY'S FOCUS: The difference between equipment availability and protection availability. A machine can remain fully functional while one of its essential explosion-protection measures has deteriorated. Today's operational question: Do our maintenance and production KPIs distinguish between equipment that is available and equipment that is demonstrably safe to operate?

⚡ DAILY Ex | 26 NOVEMBER 2026
Global Explosion Protection Watch | Head of Operations Edition
TODAY'S FOCUS: The difference between equipment availability and protection availability.
A machine can remain fully functional while one of its essential explosion-protection measures has deteriorated.
Today's operational question: Do our maintenance and production KPIs distinguish between equipment that is available and equipment that is demonstrably safe to operate?
1. USA | Deteriorating explosive inventory successfully destroyed
MATERIAL NEW DEVELOPMENT · 25 NOVEMBER
The US Army completed the controlled destruction of deteriorating lead azide stored at its Iowa ammunition facility yesterday.
Officials reported no secondary explosions or infrastructure damage and stated that initial monitoring had not detected airborne lead. Longer-term environmental assessment remains important.
Ex distinction: This concerns an inherently explosive material, rather than a conventional ATEX explosive atmosphere.
Why it matters operationally: Removing one major hazard must not introduce an unacceptable secondary hazard.
Management action: Include environmental consequences, material ageing and disposal arrangements in hazardous-inventory management.
https://www.cbsnews.com/news/iowa-army-ammunition-plant-unstable-explosives-detonation/
2. INDIA | Fire at Mumbai chemical factory
NEW INCIDENT · 25 NOVEMBER
A fire broke out yesterday at a chemical manufacturing facility in Ashirwad Industrial Estate, Goregaon East, Mumbai.
Municipal authorities confirmed the incident, with no injuries reported in the initial emergency bulletin. The chemicals involved and initiating ignition source remain unconfirmed.
Why it matters operationally: Chemical manufacturing within shared industrial estates requires consideration of escalation between neighbouring facilities, emergency access and common utilities.
Management action: Review chemical segregation, emergency isolation arrangements and potential fire or explosion propagation beyond individual production units.
3. TÜRKİYE | The relationship between heatwaves and industrial explosions
RECENT SCIENTIFIC PUBLICATION · NOVEMBER 2026
Research by Yunus Öztürk, affiliated with Gebze Technical University, examines the relationship between heatwaves and industrial explosions in Türkiye using accident data from 2020–2023.
The paper appears in the November 2026 edition of the Journal of Occupational and Environmental Medicine, Volume 68, Issue 11, pages 883–890.
The available abstract confirms the research scope, but the complete statistical findings could not be verified for today's edition.
Why it matters operationally: Increasing ambient temperatures can affect equipment cooling, solvent evaporation, machinery surface temperatures, ventilation performance and certified operating limits.
Management action: Compare actual maximum operating temperatures against equipment certification, manufacturer limitations and original explosion-risk assessments.
https://doi.org/10.1097/JOM.0000000000003727
4. GLOBAL | IECEx national differences - international certification does not eliminate local requirements
REGULATORY AND CERTIFICATION PRACTICE · EVERGREEN
The IECEx Online Bulletin provides information on national differences associated with standards operated under the IECEx system.
Its framework, supported by IECEx OD 211, allows users to examine national differences by country, standard and edition.
Why it matters operationally: An internationally certified product may still require additional national approvals, markings or conformity-assessment activities before being legally placed on a particular market.
This is particularly relevant to projects involving ATEX, UKEX, INMETRO, CCC Ex, PESO and North American hazardous-location requirements.
Management action: Establish a country-specific conformity matrix before issuing equipment purchase orders for international projects.
https://www.iecex.com/resources-and-news/iecex-on-line-bulletin/
5. IECEx | Repair facility capability - what exactly has been assessed?
2026 CERTIFICATION FRAMEWORK · TECHNICAL PRACTICE
The IECEx assessor package includes IECEx 03-5, Edition 2, covering repair, overhaul and reclamation of Ex equipment, together with technical capability assessment documentation.
An IECEx-certified repair facility should not automatically be considered competent to repair every Ex protection concept or equipment category.
Why it matters operationally: Outsourcing a repair does not remove the equipment owner's responsibility to establish the suitability of the selected service provider.
Management action: Verify the facility's certified scope, applicable standards, technical limitations, personnel competence and equipment-specific repair capability before dispatching an asset.
https://www.iecex.com/certified-service-facility-scheme/operational-documents-ods/
6. TECHNOLOGY | Can a gas detector fail dangerously while appearing healthy?
GOOD ENGINEERING PRACTICE · EVERGREEN
A catalytic combustible-gas detector may suffer reduced sensitivity following exposure to substances that poison or inhibit its sensing element.
The instrument can remain powered, communicate with the control system and display a zero reading despite degraded detection capability.
Relevant technical references include the IEC 60079-29 series and manufacturer-specific operating and maintenance instructions.
Why it matters operationally: Electrical availability and communication status do not demonstrate gas-detection effectiveness.
Management action: Review sensor technology selection, contaminant exposure, functional testing, calibration intervals and the response to failed tests.
▶️ OPERATIONAL Ex USE CASE
THE FLAMEPROOF MOTOR - WHEN A COOLING FAN REPLACEMENT CHANGES THE TEMPERATURE CLASS
Illustrative scenario · Electrical and non-electrical explosion protection
An Ex d motor operating in Zone 1 requires replacement of its damaged external cooling fan.
The original spare part is unavailable. Maintenance installs a mechanically compatible alternative with the same diameter but a different blade geometry and material.
The motor runs successfully. Production resumes.
However, the replacement fan may change cooling performance, surface temperatures, mechanical clearances and electrostatic ignition hazards.
The critical Ex question: Can the original temperature classification and applicable ignition-prevention requirements still be demonstrated?
Relevant references: IEC 60079-0, IEC 60079-1, IEC 60079-19 and manufacturer documentation.
Owner: Electrical Maintenance Manager, supported by the Ex Responsible Person.
Required evidence: Original certified construction, replacement fan specifications, manufacturer acceptance or appropriate engineering assessment, thermal performance and mechanical ignition-source assessment.
STOP criterion: Do not release the motor for hazardous-area operation until continued conformity has been demonstrated.
KPI: 100% of alternative Ex-critical spare parts subject to documented technical approval.
▶️ TODAY'S CRITICAL Ex QUESTION
An Ex d motor receives a mechanically interchangeable cooling fan with different blade geometry. What must be verified?
A. Only the fan diameter.
B. Only the motor's electrical current.
C. Cooling performance, temperature classification and relevant ignition hazards. ✅
D. Only the original Ex certificate.
The replacement fan may affect thermal performance and introduce mechanical or electrostatic ignition hazards, even though the flameproof enclosure remains unchanged.
⚡ DAILY Ex | CLOSING THOUGHT
A gas detector can communicate without detecting correctly.
An Ex motor can rotate without maintaining its assessed temperature classification.
A certified repair facility can operate outside its demonstrated technical capability.
An internationally certified product can fail to meet national regulatory requirements.
Functional availability is not the same as explosion-protection availability.
For Heads of Operations, the next step is to make protection availability a measurable operational performance indicator alongside production capacity, reliability, downtime and maintenance costs.
Do not measure only whether the machine is running. Measure whether it remains safe to run.